Architecture:
NX32L
Device support:
LX4,NX-400
Firmware version:
1.94.00
This function is used to close an M-Bus connection.
Input:
handle : SYSHANDLE
A handle to the connection to close.
Returns: INT
1
- Success
0
- Not supported
-1
- Invalid handle
Declaration:
FUNCTION mbusClose : INT; VAR_INPUT handle : ACCESS SYSHANDLE; END_VAR;
Example:
INCLUDE rtcu.inc PROGRAM test; VAR mb : SYSHANDLE; rc : INT; END_VAR; BEGIN ... // Open wired M-Bus interface rc := mbusOpen(handle := mb); ... // Close wired M-Bus interface rc := mbusClose(handle := mb); ... END; END_PROGRAM;